RVD-MC-1001 FieldCheck Single-Phase Calibrator
Move single-phase meter checks to the installed service point instead of beginning with a laboratory bench. This handheld calibrator…
View specifications +
Inspect three-phase meters using a portable instrument suited to a field measurement workflow. The calibrator combines electrical parameter checks, error calculation and clock calibration, allowing procurement to focus on the service points technicians actually visit. Specify accessible test connections, reporting requirements and the inspection procedure before choosing communications and accessories. The reference table lists Voltage range as “AC 30~480V”. Agree the meters or instruments under test, test connections, acceptance criteria and result records before selecting the complete calibration setup and commissioning procedure.
Use this catalog code in your inquiry. Include the installation country, required interfaces and quantity.
Handheld calibrators, standard sources and energy meter test benches.
Discuss the open questions| Parameter | Published specification |
|---|---|
| Voltage range | AC 30~480V |
| Terminal input | 1A,5A |
| Frequency | 45~65Hz |
| Daily time error | ±0.05s/24h |
| Communication | RS232, RS485, far infrared, USB, Bluetooth or WIFI |
| Electric energy pulse | FH=3.6*108 P/W·H FL=36000 P/W·H |
| Ambient temperature | -20℃-50℃ (accuracy guaranteed) |
| Humidity | 10% - 100%, maximum absolute humidity 35g/m³ |
The RAVODEX reference is a catalog SKU. It does not replace the equipment identity in manufacturer datasheets, approvals or service records.
Technical source: Hopeland published product information. Confirm the exact variant, accessories and current documentation in your quotation.
Bring the read point, installation country and host requirements into the quotation. Confirm the exact equipment and documentation before ordering.