RVD-EM-1001 GridLink Meter Data Hub
Bring distributed meter readings into a defined utility data collection plan. This concentrator sits between field meters and the…
View specifications +
Combine three-phase prepaid measurement with time-of-use settings, stored data and load-profile collection. This meter serves projects where account operation and consumption records need a planned reporting workflow. Agree with the utility how scheduled and requested readings will be interpreted, reconciled and recovered before specifying customer-side and upstream communication configurations. The reference table lists Reference voltage (Un) as “3X110-230V/190-400V”. Confirm the service connection, communication arrangement and commissioning responsibilities with the utility team before selecting the meter configuration and planning the rollout.
Use this catalog code in your inquiry. Include the installation country, required interfaces and quantity.
Single-phase and three-phase energy meters, DIN-rail meters and data concentrator units.
Discuss the open questions| Parameter | Published specification |
|---|---|
| Reference voltage (Un) | 3X110-230V/190-400V |
| Operation voltage | 70% Un~120% Un |
| Limit of Voltage | 0% Un~120% Un |
| Basic current (In) | 5A |
| Maximum current (Imax) | 100A |
| Short-circuit current | 3,000A, <3ms, no damage or accuracy deviation after restoration |
| Frequency | 50/60Hz |
| Frequency rage | 47.5~52.5Hz |
| Accuracy class | Cl.1.0 for active energy, Cl.2 for reactive energy |
| Electrostatic discharge (ESD) | Contact discharge: 8kV Air discharge: 15kV, IEC 61000-4-2 |
| Fast transient burst | 4 KV/100 KHZ, IEC 61000-4-4 |
| Immunity to HF Fields | 80MHz-2GHz@10V/m with load; 80MHz-2GHz@30V/m with no load |
| Conducted disturbances by RF | 150kHz - 80MHz 10V/m, IEC 61000-4-6 |
| Radio Interference | CISPR 22, IEC 61000-4-2,3,4,6 |
| Surge Immunity | 30KA/KV , 4/10S against lightening, IEC 61000-4-5 |
| Voltage circuit | <2W, 8VA @230V |
| Current circuit | <1VA @ Base current (Ib) |
| Impulse voltage (1.2/50µS) | >8KV coil to contact; >4KV contact to contact |
| AC voltage (1MIN, 50HZ) | 4KV coil to contact; 2KV contact to contact |
| Operating Temperature | -25º C~75º C |
| Storage Temperature | -40º C~85º C |
| Humidity | average ≤95%, maximum ≤100%, non-condensing |
| Altitude | ≤3000m |
The RAVODEX reference is a catalog SKU. It does not replace the equipment identity in manufacturer datasheets, approvals or service records.
Technical source: Hopeland published product information. Confirm the exact variant, accessories and current documentation in your quotation.
Bring the read point, installation country and host requirements into the quotation. Confirm the exact equipment and documentation before ordering.